Letter from the Editor: Welcome to the September 2008 issue of Fire Protection Engineering Emerging Trends, Fire Protection Engineering magazine's 8-time-per-year e-newsletter that deploys on the off-months of the magazine. Each issue will highlight a new trend and/or innovation in the fire protection engineering industry. This issue will focus on the expansion of the scope of NFPA 720.
Please enjoy the September issue and thank you for your continued support!
Sincerely,

Morgan J. Hurley, P.E.
NFPA 720 Scope Expands By Joe Talbert, P.E.
Background
Carbon monoxide (CO) exposure has been recognized as a significant hazard to life and safety for a number of years. Fire departments in the United States responded to approximately 61,000 non-fire carbon monoxide incidents in 2005.1 The number of non-fire CO incidents reported to the NFPA increased by about 9 percent per year from 2003 through 2005. Approximately 500 CO poisoning deaths occur per year in the U.S.2
An increasing number of local governments have adopted ordinances requiring carbon monoxide detection and warning equipment in buildings other than dwellings. Examples of the occupancies in which ordinances may require CO detection and warning include places of assembly and day care centers. Because of this trend, a different approach to CO detection and alarms was warranted.
Article continues below
ADVERTISEMENT:
SFPE Job Board
http://jobs.sfpe.org/
The Society of Fire Protection Engineers and Fire Protection Engineering magazine have extended the length of job posts on the Internet Job Board site from 30 days to 60 days. The Internet Job Board site features career opportunities in fire protection engineering.
http://jobs.sfpe.org/ is designed for communicating the availability of employment opportunities in the fire protection engineering market. This special job board is ideal both for those seeking to fill positions and those looking for employment opportunities in fire protection engineering.
Job categories include: • Consulting • Research & Testing • Government • Fire Equipment Manufacturing & Installation • Insurance • Education
Whether you're looking to make a career move, or you need to fill a fire protection engineer opening, http://jobs.sfpe.org/ is just a click away!
NFPA 720 Rewritten
The 2005 edition of this standard was titled Standard for the Installation of Carbon Monoxide Warning Equipment in Dwelling Units.3 The 2005 edition only applied to dwelling units, which were defined as "one or more rooms arranged for the use of one or more individuals living together, providing complete independent living facilities..." The 2009 edition will be entitled Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment.3 The standard now applies to all buildings in which carbon monoxide detection and warning equipment is installed, a very significant expansion of the scope of the standard.
To assist the technical committee in its efforts to develop appropriate standards for the location and spacing of carbon monoxide detectors, the Fire Protection Research Foundation (FPRF) commissioned a study entitled Development of a Technical Basis for Carbon Monoxide Detector Siting.2 This study was utilized by the technical committee to assist with the development of spacing and location requirements for CO detectors. The 2009 standard will require the following provisions for location of CO detectors in buildings other than dwelling units:
- On or near the ceiling in the immediate vicinity of fuel burning appliances and other sources of carbon monoxide.
- On every habitable level of the building based on an engineering evaluation considering potential sources and migration of carbon monoxide.
- In any area required by local statute.
Article continues below
ADVERTISEMENT:
Careers in Fire Protection Engineering
Interested in a career in fire protection engineering? Know someone who is? Pondering a new career? Visit FPEmag.com/Careers to access an exciting career guide with valuable information on the field of fire protection engineering.
The standard is patterned after NFPA 72, National Fire Alarm Code and contains requirements for detectors, notification appliances, power supplies, off-premises signal transmission and inspection, testing and maintenance of carbon monoxide systems and their components.
Provisions for carbon monoxide detectors for use in dwelling units are covered in Chapter 9. This chapter calls for the installation of carbon monoxide alarms or detectors in the following locations:
- Outside of each separate dwelling unit sleeping area in the immediate vicinity of the bedrooms.
- On every occupiable level of a dwelling unit, including basements, but excluding attics and crawl spaces.
- Other locations where required by applicable laws, codes or standards.
Joe Talbert is with Rolf Jensen & Associates.
- Flynn, J., Non-fire Carbon Monoxide Incidents Reported in 2005, Fire Analysis and Research Division, National Fire Protection Association, June 2007.
- Beyler, C., and Gottuck, D., Development of a Technical Basis for Carbon Monoxide Detector Siting Research Project Final Report, The Fire Protection Research Foundation, October 2007.
- 2008 Annual Revision Cycle Report on Comments, A2008, National Fire Protection Association, Quincy, MA, 2008.
Related Articles: FPE Summer 2008 - Mass Notification Systems: Design Challenges for the FPE In the aftermath of September 11, and again in each of the military barracks and embassy bombings, and school, college and mall shooting incidents, it has become clear to both the general public and the engineering community that emergency communications must be provided on a much grander scale. Emergency communication needs involving large numbers of people have generated the development of mass notification systems (MNS). The NFPA 72® Technical Correlating Committee has established a new chapter for all communications systems, including MNS, in the proposed 2010 edition of the National Fire Alarm Code®. READ MORE
FPE Fall 2007 - It's Not Your Father's Fire Alarm Code Anymore In fact, it's not just a fire alarm code. The National Fire Alarm Code has evolved since its roots back in the late 1800s and early 1900s. The 20071 edition has branched out to address risks and solutions for more than just fire. This article takes a look at that evolution. The next article in this series discusses how the evolution might continue in the next ten years. READ MORE
FPE Winter 2008 - It's Not Your Father's Fire Alarm Code Anymore, Continuation of a two-part series The first part of this article in the Fall 2007 issue looked at the evolution of the fire alarm signaling system standards and codes. This part discusses how the evolution might continue in the next ten years. READ MORE
FPE Summer 2004 - Projected-Beam Smoke Detectors-More Than Just a Substitute for Spot Detectors When smoke detection is the objective, projected beam smoke detectors can have a measurable performance advantage over spot-type smoke detectors. Projected-beam smoke detection can actually be more sensitive to real fires, yet less prone to nuisance alarms. Great taste and less filling. Is it possible to have both? For smoke detection, at least, the answer is a qualified yes. READ MORE
For questions concerning delivery of this e-Newsletter, please contact our Customer Service Department at (216) 931-9733 or FPEmag.com.
Copyright 2008, Penton Media, Inc. All rights reserved. This eNewsletter is protected by United States copyright and other intellectual property laws and may not be reproduced, rewritten, distributed, re-disseminated, transmitted, displayed, published or broadcast, directly or indirectly, in any medium without the prior written permission of SFPE and Penton Media, Inc.
|